Daily Q&A

How do you test a used microphone before buying it?

Answered on November 19, 2026

Bring two things: a multimeter and headphones. Measure resistance across pins 2 and 3, tap the body while listening, sweep your voice at 10 cm, 30 cm and 1 m, then look through the grille. A healthy dynamic mic reads 150-600 ohms. An open or infinite reading means the coil is broken and the mic is scrap.

Condenser mics need 48 V phantom power before any test means anything, so bring a small interface or ask the seller for one. Testing a condenser cold tells you nothing at all.

What should the meter read?

Mic typeExpected DC resistanceBad sign
Dynamic, SM58 class150-310 ohmsOpen circuit or above 1 kΩ
Dynamic handheld, Beta58 class250-400 ohmsReads 0 or infinite
Condenser, 48 VNot directly measurableNo output with phantom on
Ribbon0.1-10 ohmsDo not use a current-sending meter

For ribbon mics, skip the meter unless it is a low-current tester. A cheap multimeter can stretch a 2-micron ribbon, and a re-ribbon job costs USD 200-350.

How do you catch an intermittent fault?

Tap the body with a knuckle while the mic is live, then wiggle the cable at the connector. Any crackle, dropout or new hum points at a cold solder joint. That is a USD 20 fix for someone with a soldering iron, and a rejected unit for anyone else.

  • Tap the body: no pops, no dropouts.
  • Wiggle the XLR: no crackle.
  • Voice sweep at three distances: consistent tone.
  • Full gain, silence: count the hiss. Nothing audible is good.

What does used pricing look like?

Used dynamic mics sell at 40-60% of new: an SM58 at USD 55-80, a Beta58 at USD 90-130. Vintage condensers price by reputation, not by measured performance, so treat those offers with more suspicion.

The real bargains are venue lots: eight mics plus clips and a case. The per-unit price drops 25-35%, and the risk rises accordingly. Test every single one, not just the first two.

Does a clean mic sound better?

A clogged capsule mesh shaves 2-4 dB off everything above 8 kHz. On dynamic mics it cleans up with a soft brush and warm water. On condensers, dried residue on the capsule is permanent, and a replacement capsule can cost 60-80% of the mic’s value.

Test mics through the system you will actually use them on. Our microphones category shows current stock, and the K-array KF12 is an honest reference box for judging mic noise, because its horn does not flatter anything.

Key Takeaways

  • A working dynamic mic reads 150-600 ohms DC; an open circuit is fatal.
  • Tap the body and wiggle the XLR to find cold solder joints.
  • Condensers must be tested with 48 V phantom power applied.
  • Used dynamics run 40-60% of new, and venue lots cut another 25-35%.
  • Dirty grilles cost 2-4 dB above 8 kHz and clean up on dynamics only.